122
Class C22
Class B38
Class A62
Building violations, complaints & risk assessment
Risk assessment
Based on 22 open HPD Class C violations. How we assess risk
122
46
25 open
9
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 122 of 148 HPD violations
| Order | Class | Status | Inspection date | Description |
|---|---|---|---|---|
| 19359542 | C | Open | Nov 7, 2026 | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT BUILDING EAST AT FIRE ESCAPE, 2nd STORY |
| 19359541 | A | Open | Nov 7, 2026 | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING EAST AT FIRE ESCAPE, 2nd STORY |
| 19359540 | C | Open | Nov 7, 2026 | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF HOOK AND EYE DEVISE AT FIRE DOOR. AT PUBLIC HALL, 3rd STORY |
| 19359539 | C | Open | Nov 7, 2026 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359538 | B | Open | Nov 7, 2026 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359537 | B | Open | Nov 7, 2026 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359536 | B | Open | Nov 7, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359535 | C | Open | Nov 7, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359534 | B | Open | Nov 7, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 19359533 | B | Open | Nov 7, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' |
| 18862654 | A | Open | May 1, 2026 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 18037081 | A | Open | Jun 17, 2025 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. |
| 18037080 | A | Open | Jun 17, 2025 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 18037079 | A | Open | Jun 17, 2025 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| 18037078 | A | Open | Jun 17, 2025 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORY |
| 18037077 | A | Open | Jun 17, 2025 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT PUBLIC HALL, 1st STORY |
| 18037076 | C | Open | Jun 17, 2025 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT COMPACTOR DOOR AT PUBLIC HALL, 1st STORY |
| 17973079 | A | Open | Jun 6, 2025 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 16934821 | B | Open | Apr 29, 2024 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| 16847105 | A | Open | Apr 9, 2024 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 15828258 | A | Open | Mar 21, 2023 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 14911761 | A | Open | Feb 23, 2022 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 14174043 | A | Open | Apr 7, 2021 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 14064665 | B | Open | Mar 8, 2021 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE FOYER LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A-F'', AT WEST |
| 14064659 | A | Open | Mar 8, 2021 | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 1st STORY |
| 14064654 | A | Open | Mar 8, 2021 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A-F'', AT WEST |
| 14064651 | A | Open | Mar 8, 2021 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''A-F'', AT WEST |
| 14038403 | B | Open | Feb 23, 2021 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT WEST |
| 13793111 | A | Open | Aug 30, 2020 | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT WEST STACK AT FIRE ESCAPE |
| 13793091 | A | Open | Aug 30, 2020 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. |
| 13793089 | A | Open | Aug 30, 2020 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING |
| 13793088 | A | Open | Aug 30, 2020 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX NOTICE MISSING |
| 13793087 | A | Open | Aug 30, 2020 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 13793085 | A | Open | Aug 30, 2020 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. |
| 13793080 | B | Open | Aug 30, 2020 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13793075 | B | Open | Aug 30, 2020 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE IN THE 4th ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13793055 | B | Open | Aug 30, 2020 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13793054 | B | Open | Aug 30, 2020 | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED BX CABLE AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13793049 | B | Open | Aug 30, 2020 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13793039 | B | Open | Aug 30, 2020 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, APARTMENT AT WEST |
| 13788854 | A | Open | Aug 27, 2020 | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. |
| 13788853 | A | Open | Aug 27, 2020 | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. |
| 13788851 | A | Open | Aug 27, 2020 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. |
| 13788849 | A | Open | Aug 27, 2020 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. |
| 13788848 | A | Open | Aug 27, 2020 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 13788845 | C | Open | Aug 27, 2020 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY |
| 13788844 | A | Open | Aug 27, 2020 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY |
| 13788843 | A | Open | Aug 27, 2020 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORY |
| 13788837 | A | Open | Aug 27, 2020 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAPS ELECTRIC OUTLETS AT SOUTH, EAST AND WEST WALLS AT LOBBY AT PUBLIC HALL, 1st STORY |
| 13788753 | B | Open | Aug 27, 2020 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPED 2 RADIATOR SHUT OFF VALVES AT NORTH WALL AT PUBLIC HALL, 3rd STORY |
| 13771428 | A | Open | Aug 18, 2020 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WINDOW ARCHWAY, 5TH WINDOW FROM EAST AT SOUTH AT PUBLIC HALL, 1st STORY |
| 13771422 | B | Open | Aug 18, 2020 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WINDOW ARCHWAY, 5TH WINDOW FROM EAST AT SOUTH AT PUBLIC HALL, 1st STORY |
| 13770844 | A | Open | Aug 18, 2020 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 13770841 | A | Open | Aug 18, 2020 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL |
| 13770840 | A | Open | Aug 18, 2020 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL |
| 13770838 | A | Open | Aug 18, 2020 | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL |
| 13770833 | A | Open | Aug 18, 2020 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL |
| 13770827 | A | Open | Aug 18, 2020 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL |
| 13770817 | C | Open | Aug 18, 2020 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT WEST |
| 13770814 | B | Open | Aug 18, 2020 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SILICONE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT WEST |
| 13770788 | B | Open | Aug 18, 2020 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT WEST |
| 12973369 | B | Open | Mar 21, 2019 | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE FACIA PLATE AT 2ND AND 4TH STORIES BALCONIES AT 1st FIRE ESCAPE FROM NORTH AT EAST |
| 12973352 | B | Open | Mar 21, 2019 | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE FACIA PLATE AT 6TH STORY BALCONY AT 1st FIRE ESCAPE FROM NORTH AT WEST |
| 12973346 | C | Open | Mar 21, 2019 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOORS LOCKED AT BOILER ROOM |
| 12973339 | C | Open | Mar 21, 2019 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM NOTICE MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12751746 | A | Open | Nov 10, 2018 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 12751745 | C | Open | Nov 10, 2018 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12751744 | A | Open | Nov 10, 2018 | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY |
| 12751743 | A | Open | Nov 10, 2018 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| 12751742 | A | Open | Nov 10, 2018 | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| 12751741 | A | Open | Nov 10, 2018 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12751740 | A | Open | Nov 10, 2018 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12310266 | B | Open | Mar 28, 2018 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ROTTEN LINTELS AT ALL CELLAR WINDOWS,AT WEST EXTERIOR WALL |
| 12310254 | C | Open | Mar 28, 2018 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12310248 | A | Open | Mar 28, 2018 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| 12310247 | A | Open | Mar 28, 2018 | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY |
| 12310242 | A | Open | Mar 28, 2018 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY |
| 12310239 | A | Open | Mar 28, 2018 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| 12310237 | A | Open | Mar 28, 2018 | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| 12310233 | A | Open | Mar 28, 2018 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX NOTICE MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12310231 | A | Open | Mar 28, 2018 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT WALL AT PUBLIC HALL, 1st STORY |
| 12310222 | B | Open | Mar 28, 2018 | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE IN THE 4th ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, APARTMENT AT WEST |
| 12310217 | B | Open | Mar 28, 2018 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH FRAME AT WEST 2ND WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, APARTMENT AT WEST |
| 12310210 | B | Open | Mar 28, 2018 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, APARTMENT AT WEST |
| 12310207 | B | Open | Mar 28, 2018 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, APARTMENT AT WEST |
| 12261237 | C | Open | Feb 26, 2018 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12261236 | A | Open | Feb 26, 2018 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st PRIVATE HALLWAY , THE KITCHEN , THE 1st ROOM FROM EAST AT SOUTH, THE 2nd PRIVATE HALLWAY , THE BATHROOM , THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12260983 | A | Open | Feb 26, 2018 | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12260982 | A | Open | Feb 26, 2018 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, 1st CLOSET FROM SOUTH AT WEST WALL DOOR, 2nd CLOSET FROM SOUTH AT WEST WALL DOOR, BASEBOARD AT WEST WALL, BASEBOARD AT EAST WALL IN THE FOYER LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12260980 | B | Open | Feb 26, 2018 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12260979 | B | Open | Feb 26, 2018 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12260978 | B | Open | Feb 26, 2018 | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT ENTRANCE IN THE FOYER LOCATED AT APT 3K, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 12231837 | A | Open | Feb 8, 2018 | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY |
| 12231832 | A | Open | Feb 8, 2018 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY |
| 12231829 | A | Open | Feb 8, 2018 | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY |
| 12231827 | A | Open | Feb 8, 2018 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| 12231824 | A | Open | Feb 8, 2018 | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. AT PUBLIC HALL, 1st STORY |
| 12231820 | C | Open | Feb 8, 2018 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY |
| 12231815 | A | Open | Feb 8, 2018 | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR : MISSING AT PUBLIC HALL, 1st STORY |
| 12231772 | B | Open | Feb 8, 2018 | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES : CONSISTING OF A/C UNITS AT THE 6TH AND 3RD STORY BALCONIES OF THE WEST STACK AT THE FRONT OF THE BUILDING |
| 12231752 | A | Open | Feb 8, 2018 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT WEST |
| 11028245 | B | Open | Dec 7, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 11003434 | C | Open | Nov 15, 2015 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 5th APARTMENT FROM EAST AT SOUTH |
| 11003424 | A | Open | Nov 15, 2015 | SECTION 27-2005 ADM CODE REFIT LOWER SASH AT SOUTH 2 WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 4B, 4th STORY, 5th APARTMENT FROM EAST AT SOUTH |
| 10979542 | B | Open | Oct 26, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH SOUTH 2 WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT WEST |
| 9945032 | C | Open | Aug 17, 2013 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATING LOCK INSTALED AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| 9939536 | B | Open | Aug 12, 2013 | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE ... LOCATED AT APT 6H, 6th STORY, 4th APARTMENT FROM WEST AT NORTH |
| 9939535 | B | Open | Aug 12, 2013 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 4th APARTMENT FROM WEST AT NORTH |
| 9939532 | B | Open | Aug 12, 2013 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APROX = 10 SQ FT IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 4th APARTMENT FROM WEST AT NORTH |
| 9939525 | C | Open | Aug 12, 2013 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATING LOCK INSTALED AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| 9659106 | C | Open | Dec 1, 2012 | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO CELLAR LOCKED AT REAR YARD |
| 9651620 | B | Open | Nov 25, 2012 | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .... LOCATED AT APT 2G, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| 9651617 | C | Open | Nov 25, 2012 | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM N/A TO CELLAR , DOOR LOCKED AT BOILER ROOM |
| 9639466 | C | Open | Nov 12, 2012 | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO CELLAR AT PUBLIC HALL, 1st STORY |
| 8988017 | A | Open | Jun 18, 2011 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ENTRANCE DOOR IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5C, 5th STORY, 6th APARTMENT FROM EAST AT SOUTH |
| 8988015 | A | Open | Jun 18, 2011 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 6th APARTMENT FROM EAST AT SOUTH |
| 8988010 | B | Open | Jun 18, 2011 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 6th APARTMENT FROM EAST AT SOUTH |
| 8988004 | B | Open | Jun 18, 2011 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 6th APARTMENT FROM EAST AT SOUTH |
| 8988003 | B | Open | Jun 18, 2011 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASHES AT WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 6th APARTMENT FROM EAST AT SOUTH |
| 8848663 | C | Open | Mar 9, 2011 | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO CELLAR LOCKED AT REAR YARD |
| 8848658 | C | Open | Mar 9, 2011 | SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 5095969 | C | Open | Sep 2, 2004 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH |
Showing 25 of 46 DOB records
| Type | Number | Status | Date | Description |
|---|---|---|---|---|
| Other | 00166 | Open | Jun 23, 2024 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) |
| Other | 01065 | Open | Apr 22, 2023 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) |
| Other | 2201564 | Open | Dec 1, 2022 | FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 |
| Other | 10384 | Open | Aug 21, 2022 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021 |
| Other | 00697 | Open | Dec 22, 2021 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 00696 | Open | Dec 22, 2021 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 2102916 | Open | Dec 1, 2021 | FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 |
| Other | 00376 | Open | Nov 24, 2021 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 00446 | Open | Nov 10, 2021 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 00445 | Open | Nov 10, 2021 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Facade inspection | 909420 | Open | Aug 11, 2021 | CYCLE 9C UNSAFE REPORT FILED |
| Facade inspection | 809419 | Open | Aug 11, 2021 | CYCLE 8C UNSAFE REPORT FILED |
| Facade inspection | 01319 | Open | Apr 30, 2019 | FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 |
| Other | 02481 | Open | May 3, 2012 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Other | 02252 | Open | Jan 1, 2012 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Other | 1308JS | Open | Apr 17, 2008 | STOP WORK ORDER RESCINDED |
| Elevator | 9011/244802 | Open | Mar 18, 2008 | PVT: SATISFIED BY ISSUANCE OF FINAL CERT FOR EA/EBN |
| Other | 1301JS | Open | Mar 13, 2008 | STOP WORK ORDER RESCINDED |
| Other | 1301AM | Open | Jan 12, 2008 | STOP WORK ORDER RESCINDED |
| Elevator | 9011/140502 | Open | Aug 29, 2005 | PPN203 2YR TEST PERFORMED 10/20/06 BY PRECISION ELEV. CO CERT#429-001 |
| Elevator | 9011/140501 | Open | Aug 29, 2005 | PPN203 2YR TEST PERFORMED 10/17/06 BY PRECISIONELEV. CO CERT#429-001 |
| Elevator | 1456D-03 | Open | Dec 23, 1988 | (51) FILE BN FOR LOBBY DOOR (52) FILE BN FOR CONTROLLER INTERLOCKS CAR PANELS HALL BUTTONS CAR BUTTON PANEL (53)..CLEAN ALL EQUIPMENT |
| Elevator | 1456D-02 | Open | Dec 23, 1988 | (51) FILE FOR PANELS OR REMOVE SME (52) PROVERSE PROPER PERMIT & WORK COMPLETED ON ELEVATOR (53) CLEAN ALL EQUIPMENT (54) RENEW CAR FLOOR |
| Other | 13A02 | Open | Sep 27, 1988 | DUPLICATE OF ECB VIOLATION |
| Other | 13A01 | Open | Sep 27, 1988 | CURB RESTORED |
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 9 of 9 complaints
Water LeakHEAVY FLOW
ElectricOUTLET/SWITCH
Paint/PlasterCEILING
LeadLead Kit
Dead/Dying TreePlanted Less Than 2 Years Ago
Noise ResidentialBanging/Pounding
SewerCatch Basin Clogged/Flooding (Use Comments) (SC)
Blocked DrivewayPartial Access
Blocked DrivewayNo Access