HPD open violations
209
Building violations, complaints & risk assessment
Risk assessment
Based on 27 open HPD Class C violations. How we assess risk
209
38
11 open
39
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 209 of 245 HPD violations
| Order | Class | Status | Inspection date | Description |
|---|---|---|---|---|
| 19292414 | A | Open | Oct 12, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT BSMT-APT LL2, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT NORTH |
| 19292413 | B | Open | Oct 12, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT BSMT-APT LL2, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT NORTH |
| 19211716 | B | Open | Sep 12, 2026 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2U, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 19211715 | B | Open | Sep 12, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILE AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2U, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 19211714 | B | Open | Sep 12, 2026 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2U, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 19109222 | C | Open | Aug 1, 2026 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR |
| 19109221 | A | Open | Aug 1, 2026 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET OBSERVED AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT LL2, 1st APARTMENT FROM WEST AT NORTH |
| 19075107 | B | Open | Jul 15, 2026 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT LL2, 1st APARTMENT FROM WEST AT NORTH |
| 19075106 | B | Open | Jul 15, 2026 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT LL2, 1st APARTMENT FROM WEST AT NORTH |
| 18945455 | B | Open | May 21, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18945454 | B | Open | May 21, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18945453 | B | Open | May 21, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18750830 | A | Open | Mar 31, 2026 | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224385 | B | Open | Sep 12, 2025 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224384 | B | Open | Sep 12, 2025 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224383 | B | Open | Sep 12, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224382 | B | Open | Sep 12, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224381 | B | Open | Sep 12, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224380 | B | Open | Sep 12, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18224379 | B | Open | Sep 12, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT LL2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 18207289 | B | Open | Aug 30, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE FOYER LOCATED AT BSMT-APT LL2, 1st BSMT-APT FROM WEST AT NORTH |
| 18207287 | B | Open | Aug 30, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE 2nd BEDROOM FROM EAST AT NORTH LOCATED AT BSMT-APT LL2 |
| 18129499 | B | Open | Aug 1, 2025 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| 18129498 | C | Open | Aug 1, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| 17023193 | B | Open | Jun 5, 2024 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 17023191 | B | Open | Jun 5, 2024 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 17023189 | B | Open | Jun 5, 2024 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 17023186 | B | Open | Jun 5, 2024 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OVEN DOOR AT RANGE IN THE KITCHEN LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 17023185 | B | Open | Jun 5, 2024 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 16516165 | B | Open | Aug 6, 2023 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED APPROX 2SQFT OF MOLD AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16143595 ISSUED 06-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16143596 | A | Open | Aug 6, 2023 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR APPROX 3SQFT AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16143594 | A | Open | Aug 6, 2023 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 1SQFT WOODEN BASEBOARD IN THE KITCHEN LOCATED AT APT 2K, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15365333 | C | Open | Sep 14, 2022 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13716167 | C | Open | Feb 17, 2020 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL APROX = 12 SQ FT IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH ORIGINAL VIOLATION 13606753 ISSUED 17-FEB-20 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). |
| 13606755 | B | Open | Feb 17, 2020 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13606754 | B | Open | Feb 17, 2020 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13606752 | B | Open | Feb 17, 2020 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13606751 | B | Open | Feb 17, 2020 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st ROOM FROM EAST LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13606750 | B | Open | Feb 17, 2020 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13606749 | B | Open | Feb 17, 2020 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT LL1, 1st BSMT-APT FROM EAST AT SOUTH |
| 13129978 | C | Open | Jun 18, 2019 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13129972 | B | Open | Jun 18, 2019 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER SASH IN 2ND WINDOW FROM WEST AT NORTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13129954 | A | Open | Jun 18, 2019 | § 27-2005 ADM CODE REFIT THE LOWER SASH AT 1ST AND 2ND WINDOWS FROM WEST AT NORTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13129947 | A | Open | Jun 18, 2019 | § 27-2005 ADM CODE REFIT THE LOWER SASH AT 2ND WINDOW FROM WEST AT NORTH IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13129937 | B | Open | Jun 18, 2019 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13129933 | B | Open | Jun 18, 2019 | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 12794680 | B | Open | Dec 6, 2018 | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 12794679 | A | Open | Dec 6, 2018 | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE WINDOW FRAME IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 12794678 | B | Open | Dec 6, 2018 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, NORTH WALL AND WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 12794677 | B | Open | Dec 6, 2018 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, NORTH WALL AND WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 12740855 | C | Open | Nov 3, 2018 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 3; IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740854 | B | Open | Nov 3, 2018 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740853 | B | Open | Nov 3, 2018 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740852 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET COVER, AT WEST WALL, IN THE KITCHEN LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740851 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW TO SOUTH WALL IN THE KITCHEN LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740850 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT FLOOR TRANSITION IN THE FOYER LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740849 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SADDLE AT DOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740848 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SADDLE AT DOOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740847 | A | Open | Nov 3, 2018 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE KITCHEN LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 12740846 | B | Open | Nov 3, 2018 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 11931062 | A | Open | Aug 15, 2017 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4C, 3rd STORY |
| 11929500 | B | Open | Aug 15, 2017 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 3rd STORY |
| 10873038 | B | Open | Sep 22, 2015 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CLOSET DOORS IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH |
| 10839551 | A | Open | Aug 26, 2015 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE PRIVATE HALLWAY , THE BATHROOM , THE FOYER , THE 2nd ROOM FROM EAST, THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 10839414 | B | Open | Aug 26, 2015 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE KEY CYLINDER LOCK AT APARTMENT DOOR IN THE ENTRANCE LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 10837453 | A | Open | Aug 26, 2015 | SECTION 27-2005 ADM CODE REFIT THE CLOSET DOOR AT EAST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 10798902 | B | Open | Jul 27, 2015 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOORS IN THE KITCHEN LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741629 | A | Open | Jun 8, 2015 | SECTION 27-2005 ADM CODE REFIT CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741625 | B | Open | Jun 8, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SLIDING DOORS AT CLOSET IN THE 2nd ROOM FROM EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741616 | B | Open | Jun 8, 2015 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL APROX 10 SQ FT IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741606 | B | Open | Jun 8, 2015 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741602 | B | Open | Jun 8, 2015 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DRAWER AT BASE CABINET IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10741599 | B | Open | Jun 8, 2015 | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTELINE IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10659351 | B | Open | Apr 3, 2015 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10659350 | B | Open | Apr 3, 2015 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10659349 | B | Open | Apr 3, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 10659348 | B | Open | Apr 3, 2015 | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 10659347 | B | Open | Apr 3, 2015 | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION SINK WASTELINE IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10659346 | A | Open | Apr 3, 2015 | SECTION 27-2005 ADM CODE REFIT CLOSET DOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 10659345 | A | Open | Apr 3, 2015 | SECTION 27-2005 ADM CODE REFIT CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645169 | B | Open | Mar 24, 2015 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645126 | B | Open | Mar 24, 2015 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645085 | B | Open | Mar 24, 2015 | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645074 | B | Open | Mar 24, 2015 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING, NORTH AND EAST WALL APPROX 6 SQUARE FEET IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645059 | B | Open | Mar 24, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET DOOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10645017 | B | Open | Mar 24, 2015 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET DOORS AT SINK IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10453512 | C | Open | Nov 19, 2014 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ENTRANCE DOOR LOCATED AT APT 3T, 3rd STORY, APARTMENT AT SOUTH |
| 10453511 | A | Open | Nov 19, 2014 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 3T, 3rd STORY, APARTMENT AT SOUTH |
| 10453510 | B | Open | Nov 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR BY RADIATOR IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 3T, 3rd STORY, APARTMENT AT SOUTH |
| 10453509 | A | Open | Nov 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE OVEN DOOR GAS RANGE IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453507 | B | Open | Nov 19, 2014 | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE SINK IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453503 | A | Open | Nov 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOOR IN THE FOYER LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453502 | B | Open | Nov 19, 2014 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453501 | A | Open | Nov 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453500 | A | Open | Nov 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EAST AND WEST WALL CABINETS IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453499 | B | Open | Nov 19, 2014 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453498 | B | Open | Nov 19, 2014 | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10453497 | B | Open | Nov 19, 2014 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... MOLD SOUTH WALL BATHROOM IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 10409831 | B | Open | Oct 6, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409829 | B | Open | Oct 6, 2014 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ,(MISSING), LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409828 | B | Open | Oct 6, 2014 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409826 | B | Open | Oct 6, 2014 | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409825 | B | Open | Oct 6, 2014 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH AND WEST WALLS(APPROX. 10 SQ. FT.) IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409823 | B | Open | Oct 6, 2014 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CLOSET DOORS IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409814 | B | Open | Oct 6, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409807 | C | Open | Oct 6, 2014 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409804 | B | Open | Oct 6, 2014 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE TOP AND BOTTOM CABINETS AT EAST AND WEST WALLS IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10409796 | C | Open | Oct 6, 2014 | SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE UNDERNEATH SINK IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 10143890 | C | Open | Feb 19, 2014 | SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE 1st ROOM FROM EAST LOCATED AT APT 2J, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 10143889 | B | Open | Feb 19, 2014 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WATER DAMAGED, WARPED AND BUCKLED WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2J, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 9923317 | A | Open | Jul 30, 2013 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST, THE BATHROOM LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922381 | B | Open | Jul 30, 2013 | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922380 | B | Open | Jul 30, 2013 | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922379 | B | Open | Jul 30, 2013 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922378 | B | Open | Jul 30, 2013 | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922377 | C | Open | Jul 30, 2013 | SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922376 | B | Open | Jul 30, 2013 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9922375 | B | Open | Jul 30, 2013 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4J, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9786887 | B | Open | Mar 28, 2013 | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, APARTMENT AT NORTH , SECTION AT SOUTH |
| 9786886 | B | Open | Mar 28, 2013 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES WEST WALL IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, APARTMENT AT NORTH , SECTION AT SOUTH |
| 9786885 | B | Open | Mar 28, 2013 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3T, 3rd STORY, APARTMENT AT NORTH , SECTION AT SOUTH |
| 9786883 | C | Open | Mar 28, 2013 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ON ENTRANCE DOOR LOCATED AT APT 3T, 3rd STORY, APARTMENT AT NORTH , SECTION AT SOUTH |
| 9736869 | B | Open | Feb 13, 2013 | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CERAMIC WALL TILE SOUTH EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9736837 | B | Open | Feb 13, 2013 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING 10 SQUARE FEET IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9736799 | B | Open | Feb 13, 2013 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB IN THE BATHROOM LOCATED AT APT 3T, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 9705616 | B | Open | Jan 16, 2013 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTHWEST |
| 9705610 | C | Open | Jan 16, 2013 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6S, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTHWEST |
| 9181368 | B | Open | Oct 27, 2011 | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE , LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 9181298 | B | Open | Oct 27, 2011 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 9181297 | B | Open | Oct 27, 2011 | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN APT, IN THE ENTRANCE LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 9031467 | B | Open | Jul 22, 2011 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL, (APPROX. 2 SQUARE FEET) IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7984612 | B | Open | Jul 24, 2009 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7959944 | B | Open | Jul 11, 2009 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WASH BASIN CABINET DOOR IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7959925 | B | Open | Jul 11, 2009 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7959914 | B | Open | Jul 11, 2009 | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DRAW FROM BASE UNIT CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 7959904 | B | Open | Jul 11, 2009 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7C, 6th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7657693 | B | Open | Jan 7, 2009 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7657690 | B | Open | Jan 7, 2009 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7657685 | A | Open | Jan 7, 2009 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTH |
| 7575399 | B | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 7575394 | B | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK IN THE 1st ROOM FROM NORTH LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 7575362 | B | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 7575357 | B | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 7571138 | B | Open | Nov 13, 2008 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7571137 | B | Open | Nov 13, 2008 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7571136 | B | Open | Nov 13, 2008 | SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7571133 | B | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7571131 | A | Open | Nov 13, 2008 | SECTION 27-2005 ADM CODE REFIT CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 4U, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7503324 | B | Open | Oct 2, 2008 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7503322 | B | Open | Oct 2, 2008 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7503320 | B | Open | Oct 2, 2008 | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHTFIXTURE AT NORTH WALL IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7503318 | B | Open | Oct 2, 2008 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL UNDER SINK IN THE KITCHEN LOCATED AT APT 2B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 7451154 | B | Open | Aug 6, 2008 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, IN THE BATHROOM FROM EAST AT SOUTH LOCATED AT APT 2B, 2nd STORY, APARTMENT AT WEST |
| 7451151 | B | Open | Aug 6, 2008 | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE WASHBASIN, IN THE BATHROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, APARTMENT AT WEST |
| 7451146 | B | Open | Aug 6, 2008 | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET , IN THE BATHROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, APARTMENT AT WEST |
| 7451144 | B | Open | Aug 6, 2008 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND WEST WALLS, IN THE BATHROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, APARTMENT AT WEST |
| 6860555 | B | Open | Jul 30, 2007 | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4U, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6860540 | A | Open | Jul 30, 2007 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS THROGHOUT IN THE BATHROOM LOCATED AT APT 4U, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6860536 | B | Open | Jul 30, 2007 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4U, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6765884 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, 1st RISER FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 6765882 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT WEST WALL, 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 6765881 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6765880 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, WEST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7V, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6765879 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM SOUTH AT WEST WALL, NORTH WALL, SOUTH WALL, WEST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7V, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6765878 | C | Open | May 19, 2007 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 6759806 | B | Open | May 19, 2007 | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 6759805 | B | Open | May 19, 2007 | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE ***** IN THE ENTIRE APARTMENT LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 6759803 | B | Open | May 19, 2007 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ***WOOD FLOOR*** IN THE KITCHEN LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 6533373 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533372 | A | Open | Dec 30, 2006 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN THE FOYER LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533371 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533370 | A | Open | Dec 30, 2006 | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533369 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533368 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 6533367 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS IN THE KITCHEN LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| 6533366 | B | Open | Dec 30, 2006 | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WALL CABINET IN THE KITCHEN LOCATED AT APT 2S, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 5404148 | B | Open | Mar 15, 2005 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DEFECTED DOOR JAMB LOCK SIDE IN THE ENTRANCE LOCATED AT APT 7V, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST |
| 4772774 | B | Open | Nov 19, 2003 | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 4-T, 4th STORY, APARTMENT AT NORTH |
| 4603418 | B | Open | Jun 10, 2003 | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 7B, 6th STORY, APARTMENT AT WEST , SECTION AT NORTH |
| 4603399 | B | Open | Jun 10, 2003 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 7B, 6th STORY, APARTMENT AT WEST , SECTION AT NORTH |
| 4603391 | B | Open | Jun 10, 2003 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL. IN THE 1st ROOM FROM NORTH LOCATED AT APT 7B, 6th STORY, APARTMENT AT WEST , SECTION AT NORTH |
| 4603376 | C | Open | Jun 10, 2003 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 7B, 6th STORY, APARTMENT AT WEST , SECTION AT NORTH |
| 4465834 | C | Open | Jan 21, 2003 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK DOOR IN THE ENTRANCE LOCATED AT APT 5U, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 4465824 | B | Open | Jan 21, 2003 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 5U, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST |
| 4374059 | B | Open | Oct 12, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 2S, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| 4374058 | B | Open | Oct 12, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL UNDER WINDOWS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2S, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| 4372832 | B | Open | Oct 12, 2002 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING, TENANT, MR. STANEY HENRY IN THE ENTIRE APARTMENT LOCATED AT APT 4S, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| 4372791 | B | Open | Oct 12, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, WEST, NORTH & EAST WALL IN THE KITCHEN LOCATED AT APT 4S, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| 4372779 | B | Open | Oct 12, 2002 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING, TENANT MR. DANIEL ALEXANDER IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 4372735 | B | Open | Oct 12, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3T, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 4363700 | B | Open | Oct 5, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 4363699 | B | Open | Oct 5, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 4363306 | B | Open | Oct 5, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3U, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH |
| 4363227 | B | Open | Oct 5, 2002 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING ( Ms. JACOB) IN THE ENTIRE APARTMENT LOCATED AT APT 7P, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 4363190 | B | Open | Oct 5, 2002 | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7B, 6th STORY, SECTION AT SOUTH |
| 4362763 | B | Open | Oct 4, 2002 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING (CABRARA) IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 6th STORY, 4th APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 4361664 | C | Open | Oct 3, 2002 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED DOOR LOCK IN THE ENTRANCE LOCATED AT APT 4C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 4129772 | C | Open | Mar 6, 2002 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED DOUBLE CYLINDER LOCK INSTALLED AT DOOR IN THE ENTRANCE LOCATED AT APT 2V, 1st STORY, 4th APARTMENT FROM SOUTH AT WEST |
| 3471058 | B | Open | Apr 27, 2000 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE MR. J. WILTSHIRE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, APARTMENT AT NORTHEAST |
| 3380989 | C | Open | Jan 10, 2000 | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK AT ENTRANCE DOOR IN THE FOYER LOCATED AT APT 3P, 3rd STORY |
| 1658515 | B | Open | Sep 15, 1998 | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE 2 STY NORTHWEST APT 2C JOLY , SECTION '' '' |
| 1658452 | C | Open | Jun 22, 1994 | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT PEELING PAINT & PLASTER NORTH & WEST WALLS BATHROOM 6 STY APT 6V ER1 94018687. , SECTION '' '' |
| 1658451 | C | Open | Jun 22, 1994 | SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT PEELING PAINT & PLASTER CEILING BATHROOM 6 STY APT 6V AUGUSTE 9410412 ER1 94018687. , SECTION '' '' |
| 1658351 | C | Open | Aug 20, 1991 | SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING NORTH AND WEST WALLS WINDOW FRAMES SASHES AND SILL CENTER ROOM 6 STY NORTHEAST APT 7F CONNELL 469 6775 ER1 2321346. , SECTION '' '' |
| 1658342 | B | Open | Mar 13, 1987 | D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 3 STY SOUTHEAST APT 3G. , SECTION '' '' |
| 1658324 | B | Open | May 30, 1985 | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY LOCK ENTRANCE DOOR 2 STY APT 3T. LOCATED AT APT 3T |
| 1658319 | B | Open | May 30, 1985 | D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES 5 STY APT 6T THRU OUT. LOCATED AT APT 6T |
| 1658318 | B | Open | May 30, 1985 | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY LOCK ENTRANCE DOOR 6 STY APT 7B. LOCATED AT APT 7B |
| 1658317 | B | Open | May 30, 1985 | D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY LOCK ENTRANCE 6 STY APT 7P. , SECTION '' '' |
Showing 11 of 38 DOB records
| Type | Number | Status | Date | Description |
|---|---|---|---|---|
| Other | 10214 | Open | Jun 23, 2024 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2023 |
| Elevator | 09946 | Open | Sep 6, 2019 | VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST |
| Other | 13076 | Open | Dec 13, 2011 | VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT |
| Elevator | 9011/202491 | Open | Jun 1, 2007 | PPN203 5 YEAR TEST PERFORMED 06/13/2007 BY ELEVATOR TESTING CO. CERT.#493/001 |
| Elevator | 9011/202490 | Open | Jun 1, 2007 | PPN203 5 YEAR TEST PERFORMED 06/13/2007 BY ELEVATOR TESTING CO. CERT.#493/001 |
| Elevator | 90113113889 | Open | Dec 3, 2004 | PPN203 5 YEAR TEST PERFORMED 06/13/2007 BY ELEVATOR TESTING CO. CERT.#493/001 |
| Elevator | 9013/373869 | Open | Jun 2, 2003 | PPN203 5 YEAR TEST PERFORMED 06/13/2007 BY ELEVATOR TESTING CO. CERT.#493/001 |
| Elevator | 9013/373868 | Open | Jun 2, 2003 | PPN203 5 YEAR TEST PERFORMED 06/13/2007 BY ELEVATOR TESTING CO. CERT.#493/001 |
| Elevator | 9444/352786 | Open | Apr 10, 2002 | AS PER INSPECTOR ROUTE SHEET |
| Elevator | 1448D/05 | Open | May 18, 1990 | (74)PROVIDE CAPACITY PLATE |
| Elevator | 1448D/04 | Open | May 18, 1990 | (74)PROVIDE CAPACITY PLATE |
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 39 of 39 complaints
Blocked DrivewayNo Access
Blocked DrivewayNo Access
Water LeakDAMP SPOT
Unsanitary ConditionMOLD
PlumbingBASIN/SINK
GeneralVENTILATION SYSTEM
Water LeakSLOW LEAK
Damaged TreeBranch or Limb Has Fallen Down
NoiseConstruction
Illegal ParkingCommercial Overnight Parking
Unsanitary ConditionMOLD
Indoor Air QualityUnsafe Mold Cleanup
Water LeakSLOW LEAK
Flooring/StairsFLOOR
Paint/PlasterWALL
Unsanitary ConditionMOLD
Water LeakSLOW LEAK
Unsanitary ConditionMOLD
Illegal ParkingBlocked Sidewalk
RodentRat Sighting
Unsanitary ConditionMOLD
Unsanitary ConditionMOLD
Paint/PlasterWALL
Paint/PlasterCEILING
Flooring/StairsFLOOR
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterAPARTMENT ONLY
Noise ResidentialLoud Music/Party
Noise ResidentialLoud Music/Party
Noise ResidentialLoud Music/Party