HPD open violations
131
Class C45
Class B70
Class A16
Building violations, complaints & risk assessment
Risk assessment
Based on 45 open HPD Class C violations. How we assess risk
131
15
3 open
0
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 131 of 404 HPD violations
| Order | Class | Status | Inspection date | Description |
|---|---|---|---|---|
| 19358418 | C | Open | Nov 6, 2026 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 41st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 19358417 | C | Open | Nov 6, 2026 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 41st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 19358416 | C | Open | Nov 6, 2026 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 41st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 19358415 | C | Open | Nov 6, 2026 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4L, 41st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 19358414 | C | Open | Nov 6, 2026 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BOILER ROOM |
| 19358413 | A | Open | Nov 6, 2026 | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A STOP AT TOP OF GUIDE RODS SO AS TO PREVENT REMOVAL OF DROPLADDER AT REAR STACK AT FIRE ESCAPE |
| 18853968 | A | Open | May 1, 2026 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 18319833 | B | Open | Oct 23, 2025 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEM AT PUBLIC HALL, 3rd STORY |
| 18318395 | B | Open | Oct 22, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT |
| 18318394 | B | Open | Oct 22, 2025 | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. |
| 18290924 | A | Open | Oct 12, 2025 | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 1st STORY |
| 18290923 | B | Open | Oct 12, 2025 | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. |
| 18290922 | B | Open | Oct 12, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARD |
| 18272909 | B | Open | Oct 4, 2025 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE AT PUBLIC HALL, 2nd STORY |
| 18272908 | B | Open | Oct 4, 2025 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORY |
| 18272907 | B | Open | Oct 4, 2025 | 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF WASP IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272906 | C | Open | Oct 4, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272905 | B | Open | Oct 4, 2025 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272904 | B | Open | Oct 4, 2025 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272903 | B | Open | Oct 4, 2025 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272902 | C | Open | Oct 4, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER PREVENTING EGRESS TO FIRE ESCAPE IN THE 6th ROOM FROM NORTH LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18272900 | B | Open | Oct 4, 2025 | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE UNDER WASHBASIN IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 18247565 | A | Open | Sep 23, 2025 | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED |
| 18247564 | B | Open | Sep 23, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE THE WASTE COLLECTIONS AREA, GARBAGE, WASTE FOOD PRESENTED ST FLOOR, AT FRONT AREAWAY AT NORTH , SECTION ''FRONT'' |
| 18247563 | C | Open | Sep 23, 2025 | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT ,THE WASTE COLLECTIONS AREA, FRESH RATS DROPPINGS PRESENTED, AT FRONT AREAWAY AT NORTH , SECTION ''FRONT'' |
| 18247562 | B | Open | Sep 23, 2025 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER LIDS AT REGULAR TRASH BINS, AT FRONT AREAWAY AT NORTH |
| 18203459 | B | Open | Sep 3, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT |
| 18203458 | B | Open | Sep 3, 2025 | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. |
| 18203457 | B | Open | Sep 3, 2025 | § 27-2005 HMC: REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 18203455 | C | Open | Sep 3, 2025 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 18198049 | B | Open | Aug 31, 2025 | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. |
| 18198048 | B | Open | Aug 31, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT |
| 18084756 | C | Open | Jul 12, 2025 | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT BUILDING FRONT |
| 18084755 | B | Open | Jul 12, 2025 | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. |
| 18084754 | B | Open | Jul 12, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE AND HOUSEHOLD ITEMS AT BUILDING FRONT |
| 17964382 | A | Open | Jun 6, 2025 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 17879538 | C | Open | May 8, 2025 | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT BUILDING FRONT YARD |
| 17879536 | B | Open | May 8, 2025 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS (COMPUTER TABLE, BOXES, MOBILE HEATER, ETC) AT PUBLIC HALL, 4th STORY |
| 17879535 | B | Open | May 8, 2025 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS (BIKE, TOYES, BABY STROLLER, SHOES, ETC) AT PUBLIC HALL, 3rd STORY |
| 17879534 | A | Open | May 8, 2025 | § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS NUMBER ON WALL, ALL STORIES AT PUBLIC HALL |
| 17879532 | A | Open | May 8, 2025 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879531 | B | Open | May 8, 2025 | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879530 | B | Open | May 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879529 | C | Open | May 8, 2025 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES ON DOOR IN THE ENTRANCE LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879528 | B | Open | May 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879527 | B | Open | May 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL, SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879526 | B | Open | May 8, 2025 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING INSIDE CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17879525 | B | Open | May 8, 2025 | § 27-2005 ADM CODE PROVIDE LIDS FOR GARAGE CANS, BUILDING FRONT YARD |
| 17879524 | A | Open | May 8, 2025 | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY |
| 17862590 | B | Open | Apr 30, 2025 | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE APPROX 3 CUBIC YARDS OF BAGGED TRASH, LOOSE RUBBISH, AND ABANDONED HOUSEHOLD ITEMS AT BUILDING FRONT YARD, 1st STORY |
| 17317046 | C | Open | Oct 2, 2024 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH |
| 17009948 | B | Open | May 28, 2024 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 3rd STORY |
| 17009946 | B | Open | May 28, 2024 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY |
| 16832938 | A | Open | Apr 8, 2024 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 16721062 | C | Open | Mar 6, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16721061 | B | Open | Mar 6, 2024 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16721060 | B | Open | Mar 6, 2024 | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC WIRE AT CEILING AT FRONT AT BASEMENT |
| 16721059 | A | Open | Mar 6, 2024 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT FRONT AT BASEMENT |
| 16721058 | B | Open | Mar 6, 2024 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT FRONT AT BASEMENT |
| 16721057 | C | Open | Mar 6, 2024 | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING |
| 16436469 | C | Open | Nov 23, 2023 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM |
| 16436468 | C | Open | Nov 23, 2023 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 2nd ROOM FROM NORTH LOCATED AT BSMT-APT 3L, 3rd STORY, 1st BSMT-APT FROM NORTH AT EAST |
| 16414100 | B | Open | Nov 20, 2023 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16414099 | B | Open | Nov 20, 2023 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16414096 | B | Open | Nov 20, 2023 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16373760 | C | Open | Nov 11, 2023 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM |
| 16373759 | C | Open | Nov 11, 2023 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16366150 | C | Open | Nov 8, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16357781 | C | Open | Nov 3, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE IN THE ENTRANCE LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16357780 | C | Open | Nov 3, 2023 | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16357779 | C | Open | Nov 3, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BOILER ROOM DOOR AT BASEMENT |
| 16293887 | A | Open | Oct 7, 2023 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL AND CEILING AT PUBLIC HALL, 3rd STORY |
| 16293886 | B | Open | Oct 7, 2023 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT EAST WALL AND CEILING AT PUBLIC HALL, 3rd STORY |
| 16293885 | B | Open | Oct 7, 2023 | § 27-2005 HMC: REFIT SCUTTLE HATCH DOOR AT ROOF AT PUBLIC HALL, 4th STORY |
| 16066636 | C | Open | Jun 28, 2023 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT 1ST STORY PUBLIC HALL TO BASEMENT AT BOILER ROOM |
| 16066634 | B | Open | Jun 28, 2023 | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS SUPPLY FOR COOKING IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16339470 | B | Open | Jun 21, 2023 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 1 SQ. FT. AT NORTH WALL, AND 2 SQ. FT. AT CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16049986 ISSUED 21-JUN-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16049990 | C | Open | Jun 21, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BOILER ROOM DOOR AT BASEMENT |
| 16049989 | C | Open | Jun 21, 2023 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16049988 | B | Open | Jun 21, 2023 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16049987 | B | Open | Jun 21, 2023 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL AND CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16042717 | B | Open | Jun 16, 2023 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BOILER ROOM |
| 16042716 | C | Open | Jun 16, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BOILER ROOM AT CELLAR |
| 16042714 | B | Open | Jun 16, 2023 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 16035092 | C | Open | Jun 13, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16035091 | C | Open | Jun 13, 2023 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR |
| 16035090 | C | Open | Jun 13, 2023 | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 16022798 | B | Open | Jun 5, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN WATERBUGS AT FRONT AT BASEMENT |
| 16022796 | A | Open | Jun 5, 2023 | § 27-2005 ADM CODE REMOVE THE TORN AND/OR LOOSE FLOOR COVERING AT TREAD, 9TH UP FROM BOTTOM AT PUBLIC HALL STAIRS, 1st STORY |
| 15961853 | B | Open | May 2, 2023 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,,THE CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15961847 | B | Open | May 2, 2023 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15952673 | C | Open | Apr 25, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15952672 | C | Open | Apr 25, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15952668 | C | Open | Apr 25, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15952660 | A | Open | Apr 25, 2023 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT BASEMENT AT PUBLIC HALL |
| 15821752 | A | Open | Mar 21, 2023 | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. |
| 16037171 | B | Open | Jan 25, 2023 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1 SQ FT AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 15680297 ISSUED 25-JAN-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 15680302 | C | Open | Jan 25, 2023 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BOILER ROOM |
| 15680301 | B | Open | Jan 25, 2023 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BOILER ROOM |
| 15680300 | B | Open | Jan 25, 2023 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15680299 | B | Open | Jan 25, 2023 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15680298 | C | Open | Jan 25, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15680296 | C | Open | Jan 25, 2023 | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR IN THE 5th ROOM FROM NORTH LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13973200 | B | Open | Jan 6, 2021 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME CASING AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| 13973199 | B | Open | Jan 6, 2021 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME CASING AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3L, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| 13863748 | B | Open | Oct 20, 2020 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT EAST WINDOW LOWER SASH IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, APARTMENT AT EAST |
| 13714680 | B | Open | Jul 5, 2020 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13522644 | C | Open | Dec 27, 2019 | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF LOOSE LIGHT FIXTURE AT CEILING INSIDE THE CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13522643 | B | Open | Dec 27, 2019 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13522642 | C | Open | Dec 27, 2019 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO THE FIRE ESCAPE EXIT IN THE 5th ROOM FROM NORTH LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13661212 | B | Open | Dec 4, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 13481719 ISSUED 04-DEC-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 13482076 | A | Open | Dec 4, 2019 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 1st ROOM FROM NORTH LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| 13481717 | C | Open | Dec 4, 2019 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST |
| 13478600 | B | Open | Dec 2, 2019 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXURE AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13478597 | C | Open | Dec 2, 2019 | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CLOSET CEILNG IN THE 5th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13478592 | B | Open | Dec 2, 2019 | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF KEY OPERATED KNOB AT DOOR LEADING TO FIRE ECAPE WINDOW IN THE 5th ROOM FROM EAST LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13478589 | C | Open | Dec 2, 2019 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13473349 | B | Open | Nov 27, 2019 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13473347 | B | Open | Nov 27, 2019 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| 13659128 | B | Open | Nov 26, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 2 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13472209 ISSUED 26-NOV-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 13659127 | B | Open | Nov 26, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 2 SQ FT NORTH WALL IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 13472207 ISSUED 26-NOV-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 13472208 | C | Open | Nov 26, 2019 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 13659135 | B | Open | Nov 24, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 3 SQ FT) IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 13473093 ISSUED 24-NOV-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 13473106 | C | Open | Nov 24, 2019 | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LEADING TO CELLAR AT EAST WALL AT PUBLIC HALL, 1st STORY |
| 13473098 | C | Open | Nov 24, 2019 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13473097 | B | Open | Nov 24, 2019 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13473095 | B | Open | Nov 24, 2019 | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM WEST AT NORTH |
| 13655800 | B | Open | Nov 17, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 5 SQ. FT. CEILING IN THE BATHROOM LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 13457408 ISSUED 17-NOV-19 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 13461832 | A | Open | Nov 17, 2019 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM NORTH, THE BATHROOM , THE KITCHEN LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 13457071 | B | Open | Nov 17, 2019 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING BELOW RADIATOR AT WEST WALL. IN THE 1st ROOM FROM NORTH LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 13457070 | C | Open | Nov 17, 2019 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST |
Showing 3 of 15 DOB records
| Type | Number | Status | Date | Description |
|---|---|---|---|---|
| Other | 08349 | Open | Nov 14, 2025 | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| Other | 00196 | Open | Oct 8, 2014 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 17244 | Open | Feb 10, 1997 | 1995 BLR INSPECTION REPORT WAS RECEIVED BEFORE DEADLINE, PROOF SUBMITTED. |
Records temporarily unavailable.
Live 311 records are temporarily unavailable. Please try again later.