HPD open violations
132
Building violations, complaints & risk assessment
Risk assessment
Based on 49 open HPD Class C violations. How we assess risk
132
86
40 open
121
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 132 of 1274 HPD violations
| Order | Class | Status | Inspection date | Description |
|---|---|---|---|---|
| 19339838 | A | Open | Oct 29, 2026 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL AT PUBLIC HALL, 2nd STORY, SECTION ''SOUTH'' |
| 19339837 | B | Open | Oct 29, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT SOUTH WALL AT PUBLIC HALL, 2nd STORY, SECTION ''SOUTH'' |
| 19339836 | B | Open | Oct 29, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST'' |
| 19339835 | B | Open | Oct 29, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST'' |
| 19312433 | B | Open | Oct 20, 2026 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF DISCARDED STOVE WITH DOOR INTACT AT PUBLIC HALL, 1st STORY |
| 19312431 | B | Open | Oct 20, 2026 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 19312430 | B | Open | Oct 20, 2026 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 19304155 | C | Open | Oct 15, 2026 | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WET FLOOR SIGN AT DOOR FROM STREET TO VESTIBULE AT BASEMENT AT PUBLIC HALL |
| 19304154 | C | Open | Oct 15, 2026 | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WIRE AT DOOR FROM VESTIBLE TO 1ST STORY AT PUBLIC HALL |
| 19304153 | B | Open | Oct 15, 2026 | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIALS AT NORTH WALL AT 1ST STORY AT PUBLIC HALL |
| 19112627 | C | Open | Jul 28, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 1ST AND 4TH CONCRETE TREAD UP FROM BOTTOM AT 2ND SET OF STAIRS AT FRONT OF BUILIDNG |
| 19112625 | C | Open | Jul 28, 2026 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 1ST AND 4TH CONCRETE TREAD UP FROM BOTTOM AT 1ST SET OF STAIRS AT FRONT OF BUILDING |
| 19112594 | A | Open | Jul 28, 2026 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT PUBLIC HALL, 3rd STORY |
| 19112555 | A | Open | Jul 28, 2026 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 19070903 | B | Open | Jul 9, 2026 | (B) 27-2142(A) HMC: THE FOLLOWING DWELLING UNITS WERE REOCCUPIED WHILE BEING SUBJECT TO AN ORDER TO REPAIR/VACATE ORDER ISSUED BY THE DEPARTMENT; FILE FOR A DISMISSAL REQUEST RELATED TO THE ISSUED ORDER (SEE WWW.NYC.GOV/HPD). IN THE ENTIRE APARTMENT LOCATED AT APT 4M, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| 18994398 | B | Open | Jun 10, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING AT PUBLIC HALL, 1st STORY |
| 18945352 | A | Open | May 21, 2026 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND NORTH EAST WALL AT PUBLIC HALL, 1st STORY |
| 18945350 | B | Open | May 21, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 1st STORY |
| 18946029 | C | Open | May 15, 2026 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 18929011 | A | Open | May 13, 2026 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND EAST WALL AT PUBLIC HALL, 1st STORY |
| 18929009 | B | Open | May 13, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING AT PUBLIC HALL, 1st STORY |
| 18929008 | B | Open | May 13, 2026 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT 1ST WINDOW FROM EAST AT SOUTH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18929007 | C | Open | May 13, 2026 | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE PIPE OF THE SINK IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18929006 | B | Open | May 13, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18929003 | C | Open | May 13, 2026 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET IN THE ENTRANCE LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18929002 | B | Open | May 13, 2026 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18929001 | C | Open | May 13, 2026 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18928997 | B | Open | May 13, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18928996 | B | Open | May 13, 2026 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18928994 | B | Open | May 13, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18928993 | B | Open | May 13, 2026 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' |
| 18505555 | C | Open | Dec 14, 2025 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT VESTIBULE DOOR , 1st STORY |
| 18505554 | C | Open | Dec 14, 2025 | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM |
| 18505548 | C | Open | Dec 14, 2025 | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5N, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 18179116 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179115 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, NORTH WALL, EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179114 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME, 1st DOOR FRAME FROM SOUTH AT WEST WALL, SOUTH WALL, EAST WALL, WEST WALL IN THE FOYER LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179113 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE KITCHEN LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179112 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT NORTH WALL, NORTH WALL, EAST WALL, WEST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179111 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME, 1st DOOR FRAME FROM WEST AT NORTH WALL, WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18179110 | C | Open | Aug 18, 2025 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL, 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE BATHROOM LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18168969 | C | Open | Aug 18, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18168968 | C | Open | Aug 18, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 18099870 | C | Open | Jul 15, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 18099869 | C | Open | Jul 15, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 17913707 | C | Open | May 20, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE TO ALL WALLS AND CEILING THROUGHTOUT APARTMENT 3M LOCATED AT APT, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17869227 | C | Open | May 3, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2M, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 17825571 | C | Open | Apr 9, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 4M, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''L'', AT NORTH |
| 17824405 | C | Open | Apr 8, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 6M, 6th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''L'', AT NORTH |
| 17823833 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 17823832 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 17823830 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT NORTH |
| 17823811 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 4M, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| 17823809 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4M, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTH |
| 17823801 | B | Open | Apr 8, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE FOYER LOCATED AT APT 6N, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 17823800 | C | Open | Apr 8, 2025 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT 6N, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 17823790 | C | Open | Apr 8, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DECKING AND ASPHALT MATERIAL AT ROOF , SECTION AT NORTH |
| 18051255 | B | Open | Feb 19, 2025 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT EAST WALL AND WINDOW CASING IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' ORIGINAL VIOLATION 17705949 ISSUED 19-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 18015429 | B | Open | Feb 11, 2025 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT SOUTH WALL AND WINDOW CASING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' ORIGINAL VIOLATION 17686673 ISSUED 11-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17686701 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN AND MISSING VINYL FLOOR TILES CREATING TRIP HAZARD IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 17686695 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 17686691 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN AND LIFTING VINYL FLOOR TILES CREATING TRIP HAZARD IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 17686690 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN AND MISSING VINYL FLOOR TILES CREATING TRIP HAZARD IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 17686681 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686680 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686679 | B | Open | Feb 11, 2025 | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686678 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686677 | B | Open | Feb 11, 2025 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR SHUT-OFF KNOB IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686676 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686675 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686674 | B | Open | Feb 11, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17686672 | B | Open | Feb 11, 2025 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''SOUTH'' |
| 17671936 | A | Open | Feb 4, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17671935 | A | Open | Feb 4, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17671934 | A | Open | Feb 4, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17671932 | B | Open | Feb 4, 2025 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17671931 | B | Open | Feb 4, 2025 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17671930 | A | Open | Feb 4, 2025 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 17668040 | A | Open | Jan 29, 2025 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE FOYER , THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 17659138 | C | Open | Jan 29, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 17659137 | C | Open | Jan 29, 2025 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 17659136 | B | Open | Jan 29, 2025 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 17913262 | B | Open | Jan 19, 2025 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE CEILING IN THE FOYER LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' ORIGINAL VIOLATION 17635011 ISSUED 19-JAN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17913261 | B | Open | Jan 19, 2025 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2G, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''R'' ORIGINAL VIOLATION 17635004 ISSUED 19-JAN-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17647755 | B | Open | Sep 24, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT THE CEILING IN THE BATHROOM LOCATED AT APT 5G, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''south'' ORIGINAL VIOLATION 17297933 ISSUED 24-SEP-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17548287 | B | Open | Aug 11, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT EAST WALL IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH ORIGINAL VIOLATION 17184293 ISSUED 11-AUG-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17184300 | C | Open | Aug 11, 2024 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH |
| 17272099 | B | Open | May 15, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ON CEILING APPROX. 24 SQ FT. AND WEST WALL APPROX 4 SQ FT. AT LOBBY, 1st STORY ORIGINAL VIOLATION 16973982 ISSUED 15-MAY-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 17272098 | B | Open | May 15, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... ON CEILING APPROX. 4 SQ FT AND EAST WALL APPROX. 2 SQ FT. IN THE FOYER LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16973964 ISSUED 15-MAY-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16973981 | B | Open | May 15, 2024 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE TREAD 2ND UP TO 1ST STORY AT LOBBY, 1st STORY |
| 16973975 | C | Open | May 15, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR LOOSE AND UNKEYED PLASTERED CEILING APPROX. 132 SQ FT IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 17284913 | B | Open | May 13, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WINDOW FRAME APPROXIMATELY 6 SQ.FT IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16967663 ISSUED 13-MAY-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16967670 | C | Open | May 13, 2024 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH |
| 17105448 | B | Open | Mar 7, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQ FT AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16726449 ISSUED 07-MAR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16726447 | C | Open | Mar 7, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16726443 | B | Open | Mar 7, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16696861 | B | Open | Feb 24, 2024 | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 16696860 | B | Open | Feb 24, 2024 | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 16696859 | B | Open | Feb 24, 2024 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 16696858 | B | Open | Feb 24, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH |
| 16693227 | A | Open | Feb 20, 2024 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING BULKHEAD, AT PUBLIC HALL, 6th STORY, SECTION AT SOUTH |
| 16960740 | B | Open | Jan 6, 2024 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING ( APPROX 2 SQFT) AND SOUTH WALL ( APPROX 3 SQFT) IN THE BATHROOM LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16570591 ISSUED 06-JAN-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 16570596 | B | Open | Jan 6, 2024 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE ENTRANCE LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16570593 | C | Open | Jan 6, 2024 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MISSING/ LIFTING VINYL TILES AT FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16570590 | C | Open | Jan 6, 2024 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CRACKED/ LIFTING VINYL TILES AT FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16570587 | C | Open | Jan 6, 2024 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16570586 | C | Open | Jan 6, 2024 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16564345 | B | Open | Jan 3, 2024 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSISTING OF VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 17452197 | C | Open | Dec 4, 2023 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15 SQ.FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16497857 ISSUED 04-DEC-23 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). |
| 16497856 | C | Open | Dec 4, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16497854 | C | Open | Dec 4, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH |
| 16259223 | C | Open | Sep 28, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 16259222 | C | Open | Sep 28, 2023 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH |
| 15756263 | A | Open | Mar 5, 2023 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT APT2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15756260 | A | Open | Mar 5, 2023 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED CERAMICS FLOOR (WALK-IN AREA) IN THE BATHROOM LOCATED AT APT APT2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| 15660067 | B | Open | Sep 9, 2022 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 4 SQ. FT. AT THE CEILING IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' ORIGINAL VIOLATION 15356502 ISSUED 09-SEP-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 15356506 | B | Open | Sep 9, 2022 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR SLOPPING IN THE PRIVATE HALLWAY LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH'' |
| 15329198 | C | Open | Mar 22, 2022 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPROX 5 SQ. FT AND WINDOW FRAME APPROX 5 SQ. FT IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH ORIGINAL VIOLATION 15042219 ISSUED 22-MAR-22 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). |
| 15044537 | A | Open | Mar 10, 2022 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WEST WALL BULKHEAD, AT PUBLIC HALL, 6th STORY, SECTION AT NORTH |
| 15044517 | B | Open | Mar 10, 2022 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WEST WALL APPROX. 20 SQ. FT. IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST |
| 15117971 | B | Open | Dec 18, 2021 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT WEST WALL AND 2 SQ FT AT NORTH WALL IN THE BATHROOM LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''north'', 2nd FROM WEST AT NORTH ORIGINAL VIOLATION 14733193 ISSUED 18-DEC-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 14733191 | A | Open | Dec 18, 2021 | § 27-2005 ADM CODE REFIT DOORS AT BASE CABINET IN THE KITCHEN LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''north'', 2nd FROM WEST AT NORTH |
| 14733189 | C | Open | Dec 18, 2021 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''north'', 2nd FROM WEST AT NORTH |
| 14733188 | C | Open | Dec 18, 2021 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''north'', 2nd FROM WEST AT NORTH |
| 14101801 | B | Open | Nov 30, 2020 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 3 SQ. FT. AT CEILING IN THE BATHROOM LOCATED AT APT 3I, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH ORIGINAL VIOLATION 13918227 ISSUED 30-NOV-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). |
| 12956076 | B | Open | Mar 12, 2019 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX. 14 SQ. FT. AT EAST WALL IN THE BATHROOM LOCATED AT APT 2I, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH |
| 12575676 | C | Open | Sep 10, 2018 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 2; WG TO REPAIR = 0; MISSING WINDOW GUARD AND ONEWAY SCREWS IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 12575651 | B | Open | Sep 10, 2018 | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH |
| 12338041 | C | Open | Apr 11, 2018 | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3; WG TO REPLACE = 0; WG TO REPAIR = 2; LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 12333699 | C | Open | Apr 11, 2018 | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE FOYER LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 12333208 | B | Open | Apr 11, 2018 | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... ,,, CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST |
| 12206268 | B | Open | Jan 23, 2018 | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING HANDLE AT SHUTOFF VALVE AT RADIATOR AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM WEST AT NORTH |
Showing 40 of 86 DOB records
| Type | Number | Status | Date | Description |
|---|---|---|---|---|
| Other | 05806 | Open | Nov 14, 2025 | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION |
| Other | 25-00693 | Open | Apr 30, 2025 | ENGINEERS REPORT REQUIRED. AT TIME OF INSPECTION OBSERVED OBSERVED BULGING/CRACKED CEILING AT CENTER SECTION OF LOBBY AT 1ST STY LEVEL. |
| Other | 25-00691 | Open | Apr 30, 2025 | STRUCTURE RENDERED NON-COMPLAINT DUE TO FIRE AND SMOKE DAMAGE. AT TIME OF INSPECTION OBSERVED SMOKE DAMAGE AT PUBLIC HALL 6TH STY LEVEL AT NORTH SECTION OF BUILDING. ALSO OBSERVED BULGING/CRACKED CEILING AT CENTER SECTION OF LOBBY AT 1ST STY LEVEL. |
| Other | 2400610 | Open | Dec 1, 2024 | FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 |
| Other | 05562 | Open | Sep 23, 2024 | VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION |
| Other | 00050 | Open | Feb 21, 2024 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 07716 | Open | Apr 25, 2023 | VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION |
| Other | 00017 | Open | Nov 21, 2022 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021) |
| Facade inspection | 00827 | Open | Feb 22, 2022 | FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 |
| Other | 02056 | Open | Sep 2, 2020 | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION |
| Other | 00404 | Open | Nov 2, 2019 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Other | 00640 | Open | Aug 2, 2019 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Other | 01210 | Open | May 2, 2019 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Other | 00128 | Open | Mar 18, 2019 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2018) |
| Facade inspection | 00400 | Open | May 31, 2018 | FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 |
| Other | 00373 | Open | Mar 27, 2018 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2017) |
| Other | 10284 | Open | Feb 16, 2017 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2016) |
| Other | 30024 | Open | Sep 1, 2016 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2014 |
| Other | 00044 | Open | Sep 1, 2016 | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2015) |
| Other | 00356 | Open | Jun 2, 2016 | FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 |
| Elevator | 02938 | Open | Mar 31, 2014 | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST |
| Elevator | 02937 | Open | Mar 31, 2014 | VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST |
| Facade inspection | HAZ73469 | Open | Feb 17, 2012 | UNSAFE LOCAL LAW REPORT FILED |
| Other | 06545 | Open | Jan 6, 2006 | CIAVHA CANCELLED NEW OWNERSHIP SUBMITTED_DEED PUR 02/01/07 CRFN#2007000074963 |
| Elevator | 01619 | Open | Nov 19, 2004 | LL1081 NEW OWNER AS OF FEBRUARY 2007 |
| Elevator | 01826 | Open | Apr 21, 2004 | LL1081 NEW OWNER AS OF FEBRUARY 2007 |
| Elevator | 01487 | Open | Mar 21, 2003 | LL1081 NEW OWNER AS OF FEBRUARY 2007 |
| Elevator | 9444/265399 | Open | Dec 13, 2002 | 2P347 |
| Elevator | 9444/265398 | Open | Dec 13, 2002 | 2P346 |
| Other | 09782 | Open | Mar 26, 2002 | CIAVHA CANCELLED NEW OWNERSHIP SUBMITTED_DEED PUR 02/01/07 CRFN#2007000074963 |
| Elevator | 01890 | Open | Feb 19, 2002 | LL1081 NEW OWNER AS OF FEBRUARY 2007 |
| Elevator | 01652 | Open | Mar 8, 2001 | LL1081 NEW OWNER AS OF FEBRUARY 2007 |
| Other | 09549 | Open | Feb 7, 2000 | CIAVHA CANCELLED NEW OWNERSHIP SUBMITTED_DEED PUR 02/01/07 CRFN#2007000074963 |
| Other | 12258 | Open | Feb 10, 1997 | CIAVHA CANCELLED NEW OWNERSHIP SUBMITTED_DEED PUR 02/01/07 CRFN#2007000074963 |
| Other | 00250 | Open | Jun 9, 1994 | CIAVHA CANCELLED NEW OWNERSHIP SUBMITTED_DEED PUR 02/01/07 CRFN#2007000074963 |
| Elevator | 02259 | Open | Apr 7, 1992 | 2 |
| Elevator | 1176C07 | Open | Mar 14, 1990 | 62-REPAIR LIGHT-3-PROVIDE CAPACITY PLATE-51-PROVIDE LIGHT SWITCH- 1-CEASE USE UNTIL IS COMPLY WITH |
| Elevator | 1176C06 | Open | Mar 14, 1990 | 46-SO THAT A PROPER INSPECTION CAN BE MADE-3-PROVIDE CAPACITY PLATE-74-TEST AND TAG FOR 2 ON 5 YEAR-57-PROVIDE PROPER DOON & LIGHT & SWITCH |
| Elevator | 1289C-3 | Open | Dec 10, 1988 | (51) ENCLOSE WIRES IN BRAKE AND HOIST MOTOR |
| Elevator | 1289C-2 | Open | Dec 10, 1988 | (51) ENCLOSE WIRES ON BRAKE AND HOIST MOTOR |
311 complaints are counted by tax lot (BBL) and may include other addresses on the same lot.
Showing 121 of 121 complaints
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise CommercialLoud Music/Party
Noise CommercialLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Heat/Hot WaterAPARTMENT ONLY
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Water LeakHEAVY FLOW
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterAPARTMENT ONLY
Noise Street/SidewalkLoud Music/Party
SafetyFIRE ESCAPE
Unsanitary ConditionGARBAGE/RECYCLING STORAGE
Noise Street/SidewalkLoud Music/Party
DrinkingIn Public
DrinkingIn Public
Noise ResidentialLoud Music/Party
DrinkingIn Public
DrinkingIn Public
Noise CommercialLoud Music/Party
Noise CommercialLoud Music/Party
DrinkingIn Public
DrinkingIn Public
DrinkingIn Public
Water ConservationFire Hydrant
Water MaintenanceFire Hydrant Running Full
DrinkingIn Public
Water ConservationFire Hydrant
Water MaintenanceFire Hydrant Running Full
DrinkingIn Public
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise ResidentialLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Water MaintenanceDirty Water
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Noise Street/SidewalkLoud Music/Party
Water MaintenanceDirty Water
Water MaintenanceFire Hydrant Emergency
Water MaintenanceFire Hydrant Emergency
Water MaintenanceFire Hydrant Emergency
Water MaintenanceFire Hydrant Running Full
Water MaintenanceFire Hydrant Running Full
Illegal ParkingDouble Parked Blocking Traffic
Water QualityOdor/Taste
Noise Street/SidewalkLoud Music/Party
ObstructionTrash or Recycling
Water ConservationIllegal Use Of A Hydrant (CIN)
Dirty ConditionTrash
Water SystemHydrant Running Full (WA4)
Noise Street/SidewalkLoud Music/Party
Water SystemHydrant Running (WC3)
Water SystemHydrant Running Full (WA4)
Water SystemHydrant Running Full (WA4)
Water SystemHydrant Running Full (WA4)
Noise Street/SidewalkLoud Music/Party
Water SystemHydrant Running Full (WA4)
Water SystemFire Hydrant Emergency (FHE)
Water SystemFire Hydrant Emergency (FHE)
Water SystemFire Hydrant Emergency (FHE)
Water SystemFire Hydrant Emergency (FHE)
PlumbingTOILET
Door/WindowDOOR FRAME
Door/WindowDOOR
Unsanitary ConditionPESTS
Unsanitary ConditionPESTS
PlumbingTOILET
SafetyFIRE ESCAPE
GeneralSIGNAGE MISSING
PlumbingWATER SUPPLY
Water LeakSLOW LEAK
Paint/PlasterCEILING
Water LeakHEAVY FLOW
Unsanitary ConditionPESTS
SafetyFIRE ESCAPE
ElectricOUTLET/SWITCH
ApplianceREFRIGERATOR
Door/WindowDOOR
PlumbingBASIN/SINK
Paint/PlasterWALL
Paint/PlasterCEILING
Noise ResidentialLoud Music/Party
Noise Street/SidewalkLoud Music/Party
DrinkingIn Public
General Construction/PlumbingEgress - Doors Locked/Blocked/Improper/No Secondary Means
SafetyFIRE ESCAPE
Indoor Air QualityOther (Explain Below)
SafetyFIRE ESCAPE
Paint/PlasterCEILING
Water LeakHEAVY FLOW
Heat/Hot WaterENTIRE BUILDING
ApplianceELECTRIC/GAS RANGE
Water LeakDAMP SPOT
Water LeakHEAVY FLOW
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterENTIRE BUILDING
Consumer ComplaintBodega, Deli, or Convenience Store
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterAPARTMENT ONLY
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterENTIRE BUILDING
Heat/Hot WaterAPARTMENT ONLY
Consumer ComplaintOnline or Mail Order
Unsanitary ConditionPESTS
Unsanitary ConditionPESTS